Anti-Blooming Design

Anti-blooming shunts excess charge to drain when well exceeds threshold. Trade-off: charge dump efficiency vs full well capacity and linearity.

Model: Illustrative

Linear range (barrier)

40000 e⁻

80 % of the well

In the well

40200 e⁻

barrier + 200 e⁻ leaked, capped at 10000 e⁻

To the drain

19800 e⁻

Spilled into neighbours

0 e⁻

no blooming

Blooming onset

1.040e+6 e⁻

20.8× full well: N_b = T + (W − T)/(1 − η)

Well above the barrier

10000 e⁻

headroom the drain protects

Illustrative hard-threshold drain: below the barrier every electron is kept; above it a fraction (1 − η) still reaches the well until the well is full, and the rest spills. Real lateral and vertical overflow drains turn on gradually, so the response bends over before the barrier.

Model and references

Illustrative. A simplified model that shows trends and orders of magnitude. Don't use its numbers for design. About the tiers

A hard barrier at a fraction of the full well: above it a fixed fraction η of the extra charge goes to the drain, the rest fills the well and then spills (blooming onset N_b = T + (W − T)/(1 − η)). Real overflow drains turn on gradually through sub-threshold barrier current; η here is a lumped parameter, not a device spec.

  1. Janesick J. R. (2001). Scientific Charge-Coupled Devices. SPIE Press. Blooming, lateral and vertical overflow drains, clocked anti-blooming and their cost in full well and fill factor. doi:10.1117/3.374903
Report a problem

A wrong value, a formula, a reference, or a page that misbehaves. The report includes this page and its current inputs.